A first article check can start with the wrong BOM revision or an incomplete placement file. The E880 checks the bill of materials (BOM) and XY placement data against each other so the operator can review missing or inconsistent entries before working through the first assembled board. The built-in scanner captures the assembly, and the software shows the board image alongside the reference location to help the operator find each component. Both sides of a PCB can be imported and checked separately.
| First article check | How the E880 handles it |
|---|---|
| Program data | Cross-checks BOM and XY placement data |
| Board reference | Scanned PCBA image and on-screen component locations |
| Component checks | LCR measurements for applicable parts and optical comparison of visible markings and orientation |
| Review and release | Live inspection status and automatic reports in English or Chinese |
The E880 also supports inspection by station position when a station table is available. For a demonstration, send the BOM, XY files and station list for a representative job. Ask to see how the system flags missing references and records an unresolved check in the final report.